Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
Chin Med J (Engl) ; 2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37606001

RESUMO

BACKGROUND: Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve. METHODS: Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University. RESULTS: 3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) (n = 2) or risk of compression coronary artery (n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001). CONCLUSIONS: In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.

2.
J Cardiovasc Imaging ; 30(4): 292-304, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36280271

RESUMO

BACKGROUND: Calcium is a determinant of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI). This is based on a fixed contrast attenuation value while X-ray attenuation is patient-dependent and without considering frame expansion and PVL location. We examined the role of calcium in (site-specific) PVL after TAVI using a patient-specific contrast attenuation coefficient combined with frame expansion. METHODS: 57 patients were included with baseline CT, post-TAVI transthoracic echocardiography and rotational angiography (R-angio). Calcium load was assessed using a patient-specific contrast attenuation coefficient. Baseline CT and post-TAVI R-angio were fused to assess frame expansion. PVL was assessed by a core lab. RESULTS: Overall, the highest calcium load was at the non-coronary-cusp-region (NCR, 436 mm3) vs. the right-coronary-cusp-region (RCR, 233 mm3) and the left-coronary-cusp-region (LCR, 244 mm3), p < 0.001. Calcium load was higher in patients with vs. without PVL (1,137 vs. 742 mm3, p = 0.012) and was an independent predictor of PVL (odds ratio, 4.83, p = 0.004). PVL was seen most often in the LCR (39% vs. 21% [RCR] and 19% [NCR]). The degree of frame expansion was 71% at the NCR, 70% at the RCR and 74% at the LCR without difference between patients with or without PVL. CONCLUSIONS: Calcium load was higher in patients with PVL and was an independent predictor of PVL. While calcium was predominantly seen at the NCR, PVL was most often at the LCR. These findings indicate that in addition to calcium, specific anatomic features play a role in PVL after TAVI.

3.
Cardiovasc Revasc Med ; 44: 67-70, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35787831

RESUMO

BACKGROUND: Multislice computed tomography (MSCT) may reveal hypo-attenuated leaflet thickening (HALT) and/or reduced leaflet motion (RELM) in approximately 15 % of patients after transcatheter aortic valve replacement (TAVR). These supposedly thrombogenic phenomena may be associated with neurological events and increased transprosthetic gradients. It is unclear whether oral anticoagulant therapy -specifically a factor Xa inhibitor- could affect the incidence of HALT/RELM. STUDY DESIGN: The Rotterdam EDOXaban (REDOX) trial is an investigator-initiated, single-center, prospective registry in which 100 patients with no formal indication for oral anticoagulant drugs or dual antiplatelet therapy, will receive a 3-month treatment with edoxaban, followed by a MSCT to detect HALT/RELM. The primary endpoint is the incidence of HALT at 3-months follow-up. Secondary endpoints include the incidence of RELM at 3 months; change in transprosthetic gradients at 1 year and the clinical composite endpoint of all-cause death, myocardial infarction (MI), ischemic stroke, systemic thromboembolism, valve thrombosis and major bleeding (International Society on Thrombosis and Hemostasis [ISTH] definition) at 1 year follow up. The study is powered to demonstrate with 90 % statistical power and a 0.025 alpha a 4 % incidence of HALT with edoxaban as compared to the expected 15 % rate with an antiplatelet regimen and will enroll 100 patients to account for loss of follow-up or CT-drop out. CONCLUSION: The REDOX trial will investigate the short-term effect of an Xa-inhibitor on the incidence of HALT after TAVR. (ClinicalTrials.gov Identifier: NCT04171726).


Assuntos
Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Anticoagulantes/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Inibidores do Fator Xa/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos
4.
EuroIntervention ; 18(9): 769-776, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-35712763

RESUMO

BACKGROUND: The mechanically-expandable transcatheter valve is no longer commercially available, yet clinical and echocardiographic surveillance is imperative for thousands of patients who received transcatheter aortic valve implantation (TAVI) with this platform. AIMS: We aimed to determine the incidence and mechanism of bioprosthetic valve dysfunction (BVD) following TAVI with mechanically-expandable valves. METHODS: From 2013 to 2020, all 234 patients who underwent TAVI with the LOTUS valve were included. BVD was categorised as (i) structural valve deterioration (SVD), (ii) non-structural valve dysfunction (NSVD), (iii) clinical valve thrombosis and (iv) endocarditis, according to the Valve Academic Research Consortium-3 criteria. RESULTS: The mean age was 79±7 years, 60% were male, and the mean Society of Thoracic Surgeons score was 4.2±2.9%. The technical success rate was 94% and the 30-day device success rate was 78%. All-cause mortality at 1 year was 15%; median follow-up duration was 36 (IQR 18-60) months during which 47% of patients died. One hundred and three patients had ≥1 type of BVD (44%), which predominantly consisted of NSVD (39%, mostly because of ≥moderate patient-prosthesis mismatch). BVD during follow-up included endocarditis (3.4%), clinical valve thrombosis (3.4%) and SVD (1.3%). Both endocarditis and clinically apparent valve thrombosis occurred early and late after TAVI and resulted in valve-related deaths in 38% and 13% of patients, respectively. Overall, ≥moderate haemodynamic valve deterioration occurred in 5.5% and bioprosthetic failure in 7.3%, leading to valve-related deaths in 36% of cases. CONCLUSIONS: BVD represents a relevant health issue after TAVI with a mechanically-expandable valve. Serious but reversible causes of BVD include endocarditis and clinically apparent valve thrombosis, both carrying a time-independent hazard post-TAVI.


Assuntos
Estenose da Valva Aórtica , Endocardite , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Incidência , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Endocardite/epidemiologia , Endocardite/etiologia , Desenho de Prótese
5.
J Am Soc Echocardiogr ; 35(1): 105-115.e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34389469

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) can be subclassified on the basis of its proportionality relative to left ventricular (LV) volume and function, indicating potential differences in underlying etiology. The aim of this study was to evaluate the association of FMR proportionality with FMR reduction, heart failure hospitalization and mortality after transcatheter edge-to-edge mitral valve repair (TEER). METHODS: This multicenter registry included 241 patients with symptomatic heart failure with reduced LV ejection fraction treated with TEER for moderate to severe or greater FMR. FMR proportionality was graded on preprocedural transthoracic echocardiography using the ratio of the effective regurgitant orifice area to LV end-diastolic volume. Baseline characteristics, follow-up transthoracic echocardiography, and 2-year clinical outcomes were compared between groups. RESULTS: Median LV ejection fraction, effective regurgitant orifice area and LV end-diastolic volume index were 30% (interquartile range [IQR], 25%-35%), 27 mm2, and 107 mL/m2 (IQR, 90-135 mL/m2), respectively. Median effective regurgitant orifice area/LV end-diastolic volume ratio was 0.13 (IQR, 0.10-0.18). Proportionate FMR (pFMR) and disproportionate FMR (dFMR) was present in 123 and 118 patients, respectively. Compared with patients with pFMR, those with dFMR had higher baseline LV ejection fractions (median, 32% [IQR, 27%-39%] vs 26% [IQR, 22%-33%]; P < .01). Early FMR reduction with TEER was more pronounced in patients with dFMR (odds ratio, 0.45; 95% CI, 0.28-0.74; P < .01) than those with pFMR, but not at 12 months (odds ratio, 0.93; 95% CI, 0.53-1.63; P = .80). Overall, in 35% of patients with initial FMR reduction after TEER, FMR deteriorated again at 1-year follow-up. Rates of 2-year all-cause mortality and heart failure hospitalization were 30% (n = 66) and 37% (n = 76), with no differences between dFMR and pFMR. CONCLUSIONS: TEER resulted in more pronounced early FMR reduction in patients with dFMR compared with those with pFMR. Yet after initial improvement, FMR deteriorated in a substantial number of patients, calling into question durable mitral regurgitation reductions with TEER in selected patients. The proportionality framework may not identify durable TEER responders.


Assuntos
Insuficiência da Valva Mitral , Ecocardiografia , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
6.
Eur Heart J Cardiovasc Imaging ; 23(10): 1345-1353, 2022 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34322706

RESUMO

AIMS: To elucidate the frequency and clinical impact of left atrial appendage thrombus (LAAT) in patients set for transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: All patients undergoing TAVI between January 2014 and June 2020 with analysable multislice computed tomography (MSCT) for LAAT were included. Baseline and procedural characteristics were collected, pre-procedural MSCT's were retrospectively analysed for LAAT presence. The primary endpoint was defined as the cumulative incidence of any cerebrovascular event (stroke or transient ischaemic attack) within the first year after TAVI. A Cox proportional hazards model was used to identify predictors.A total of 1050 cases had analysable MSCT. Median age was 80 [interquartile range (IQR) 74-84], median Society of Thoracic Surgeons' Predicted Risk Of Mortality (STS-PROM) was 3.4% (IQR 2.3-5.5). Thirty-six percent were on oral anticoagulant therapy for atrial fibrillation (AF). LAAT was present in 48 (4.6%) of cases. Patients with LAAT were at higher operative risk [STS-PROM: 4.9% (2.9-7.1) vs. 3.4% (2.3-5.5), P = 0.01], had worse systolic left ventricular function [EF 52% (35-60) vs. 55% (45-65), P = 0.01] and more permanent pacemakers at baseline (35% vs. 10%, P < 0.01). All patients with LAAT had a history of AF and patients with LAAT were more often on vitamin K antagonist-treatment than patients without LAAT [43/47 (91%) vs. 232/329 (71%), P < 0.01]. LAAT [hazard ratio (HR) 2.94 (1.39-6.22), P < 0.01] and the implantation of more than one valve [HR 4.52 (1.79-11.25), P < 0.01] were independent predictors for cerebrovascular events. CONCLUSION: Patients with MSCT-identified LAAT were at higher risk for cerebrovascular events during the first year after TAVI.


Assuntos
Estenose da Valva Aórtica , Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Trombose , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana/métodos , Cardiopatias/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Cardiovasc Revasc Med ; 34: 40-45, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33547024

RESUMO

INTRODUCTION: We aimed to compare conduction dynamics and need for permanent pacemaker implantation (PPI) after CoreValve, Evolut R and PRO (transcatheter aortic valve replacement (TAVR)). METHODS: Patients were stratified based on conduction at baseline; Cohort A had normal conduction, Cohort B had conduction abnormalities including atrioventricular (AV)-block, fascicular block or complete bundle branch block. Three different dynamic QRS-patterns were defined: stable QRS-duration, transient QRS-prolongation and persistent QRS-prolongation. We performed multivariable regression analysis to estimate the effect of the three separate transcatheter heart valves (THV's) on need for PPI at 30 days. RESULTS: TAVR was performed with CoreValve (N = 113), Evolut R (N = 157) or Evolut PRO (N = 92). Conduction dynamics were similar between the different THVs. Overall, Evolut R and PRO showed a tendency towards less PPI compared to CoreValve (17% vs. 19% vs. 27%, P = 0.08), which was driven by a lower PPI rate in Cohort A (6% vs. 11% vs. 25%, P = 0.002). Need for PPI was restricted to patients with persistent QRS-prolongation in Cohort A (26/106) but did not correlate with conduction dynamics in Cohort B. In multivariable logistic regression analysis the use of Evolut R (OR 0.38, 95% CI 0.19-0.78, P = 0.008) and PRO (OR 0.41, 95% CI 0.19-0.91, P-value = 0.028) were independently associated with less need for PPI. CONCLUSION: The newer generations Evolut R and PRO were associated with less PPI compared to CoreValve. Acquired persistent conduction abnormalities predicted PPI after TAVR only in patients with normal conduction at baseline. Our findings may help identify eligible patients for early discharge after Evolut R/PRO TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 99(4): 1197-1205, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34837467

RESUMO

OBJECTIVES: To study the safety and feasibility of a restrictive temporary-RV-pacemaker use and to evaluate the need for temporary pacemaker insertion for failed left ventricular (LV) pacing ability (no ventricular capture) or occurrence of high-degree AV-blocks mandating continuous pacing. BACKGROUND: Ventricular pacing remains an essential part of contemporary transcatheter aortic valve implantation (TAVI). A temporary-right-ventricle (RV)-pacemaker lead is the standard approach for transient pacing during TAVI but requires central venous access. METHODS: An observational registry including 672 patients who underwent TAVI between June 2018 and December 2020. Patients received pacing on the wire when necessary, unless there was a high-anticipated risk for conduction disturbances post-TAVI, based on the baseline-ECG. The follow-up period was 30 days. RESULTS: A temporary-RV-pacemaker lead (RVP-cohort) was inserted in 45 patients, pacing on the wire (LVP-cohort) in 488 patients, and no pacing (NoP-cohort) in 139 patients. A bailout temporary pacemaker was implanted in 14 patients (10.1%) in the NoP-cohort and in 24 patients (4.9%) in the LVP-cohort. One patient in the LVP-cohort needed an RV-pacemaker for incomplete ventricular capture. Procedure time was significantly longer in the RVP-cohort (68 min [IQR 52-88.] vs. 55 min [IQR 44-72] in NoP-cohort and 55 min [IQR 43-71] in the LVP-cohort [p < 0.005]). Procedural high-degree AV-block occurred most often in the RVP-cohort (45% vs. 14% in the LVP and 16% in the NoP-cohort [p ≤ 0.001]). Need for new PPI occurred in 47% in the RVP-cohort, versus 20% in the NoP-cohort and 11% in the LVP-cohort (p ≤ 0.001). CONCLUSION: A restricted RV-pacemaker strategy is safe and shortens procedure time. The majority of TAVI-procedures do not require a temporary-RV-pacemaker.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
10.
J Clin Med ; 10(16)2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34441825

RESUMO

Selecting patients with a high chance of endured benefit from transcatheter aortic valve implantation (TAVI) is becoming relevant with changing indications and increasing number of TAVI being performed. The aim of our study was to investigate the association of the multidimensional prognostic index (MPI) based on a comprehensive geriatric assessment (CGA) on survival. The TAVI Care & Cure program is a prospective, observational registry of patients referred for TAVI at the Erasmus MC University Medical Center. Consecutive patients who underwent a complete CGA and TAVI were included. CGA components were used to calculate the MPI score. The impact of the MPI score on survival was evaluated using Cox regression. Furthermore, 376 patients were included, 143 (38.0%) patients belonged to the MPI-1 group and 233 (61.9%) patients to the MPI-2-3 group. After 3 years, 14.9% of the patients in the MPI-1 group and 30.5% of the patients in the MPI-2-3 group died (p = 0.001). Patients in MPI-1 had increased chances of overall survival in comparison with patients in MPI group 2-3 Hazard Ratio (HR) 0.57, (95% Confidence Interval (CI) 0.33-0.98)). In this study we found that the MPI tool could be useful to assess frailty and to predict which patient will have a higher chance of enduring benefit from a TAVI procedure.

12.
J Am Heart Assoc ; : e019236, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33794658

RESUMO

Background Recurrence of mitral regurgitation (MR) after surgical mitral valve repair (SMVR) varies and may require reoperation. Redo mitral valve surgery can be technically challenging and is associated with increased risk of mortality and morbidity. We aimed to assess the feasibility and safety of MitraClip as a treatment strategy after failed SMVR and identify procedure modifications to overcome technical challenges. Methods and Results This international multicenter observational retrospective study collected information for all patients from 16 high-volume hospitals who were treated with MitraClip after failed SMVR from October 29, 2009, until August 1, 2017. Data were anonymously collected. Technical and device success were recorded per modified Mitral Valve Academic Research Consortium criteria. Overall, 104 consecutive patients were included. Median Society of Thoracic Surgeons score was 4.5% and median age was 73 years. At baseline, the majority of patients (82%) were in New York Heart Association class ≥III and MR was moderate or higher in 86% of patients. The cause of MR pre-SMVR was degenerative in 50%, functional in 35%, mixed in 8%, and missing/unknown in 8% of patients. The median time between SMVR and MitraClip was 5.3 (1.9-9.7) years. Technical and device success were 90% and 89%, respectively. Additional/modified imaging was applied in 21% of cases. An MR reduction of ≥1 grade was achieved in 94% of patients and residual MR was moderate or less in 90% of patients. In-hospital all-cause mortality was 2%, and 86% of patients were in New York Heart Association class ≤II. Conclusions MitraClip is a safe and less invasive treatment option for patients with recurrent MR after failed SMVR. Additional/modified imaging may help overcome technical challenges during leaflet grasping.

13.
Int J Cardiol ; 333: 152-158, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33675890

RESUMO

Background The need for new permanent pacemaker implantation (PPI) after Transcatheter Aortic Valve Implantation (TAVI) remains a critical issue. Membranous Septum (MS) length is associated with PPI after TAVI. The aim of this study was to identify different MS thresholds for the contemporary THV-platforms. Methods This retrospective, case-control study enrolled all patients who underwent a successful TAVI procedure with contemporary THV-platforms in the Erasmus University Medical Center between January 2016 and March 2020. The follow-up period for new PPI was 30 days. MS-length was determined by Computed Tomography. Results The study consisted 653 TAVI patients with median age 80.6 years (IQR 74.7-84.8). New PPI occurred in 120 patients (18.4%). Patients with new PPI had a shorter MS-length (2.9 mm (IQR 2.3-4.3) vs. 4.2 mm (IQR 2.9-5.7), p < 0.001). MS-length < 3 mm identified a high-risk phenotype with 30.3% PPI-rate (OR 6.5 [95%CI 2.9-14.9]), MS-length 3-6 mm an intermediate-risk phenotype with 15.4% PPI-rate (OR 2.7 [95%CI 1.2-6.2]) and MS > 6 mm a low-risk phenotype with a 6.3% PPI-rate (reference). For the Lotus valve, there was no significant difference in PPI-rates between the high-risk (45.8%, OR 3.5 [95%CI 0.8-15.1]) and low-risk group (20%). By multivariate analysis MS-length, Agatston-score, use of Lotus valve, and ECG with first-degree AV block, RBBB or bifascular block were independent predictors for new PPI. Conclusion MS-length was an independent predictor for new PPI post-TAVI. Three phenotypes were found based on MS-length. MS < 3 mm was universally associated with a high risk for new PPI (>30%). MS > 6 mm represented a low-risk phenotype with PPI-rate < 10%. PPI-rate varied per THV type in the intermediate phenotype. PPI-rate with Lotus was high regardless of MS-length.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial , Estudos de Casos e Controles , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
JACC Cardiovasc Imaging ; 14(8): 1644-1658, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33744155

RESUMO

A plethora of catheter-based strategies have been developed to treat mitral valve disease. Evolving 3-dimensional (3D) multidetector computed tomography (MDCT) technology can accurately reconstruct the mitral valve by means of 3-dimensional computational modeling (3DCM) to allow virtual implantation of catheter-based devices. 3D printing complements computational modeling and offers implanting physician teams the opportunity to evaluate devices in life-size replicas of patient-specific cardiac anatomy. MDCT-derived 3D computational and 3D-printed modeling provides unprecedented insights to facilitate hands-on procedural planning, device training, and retrospective procedural evaluation. This overview summarizes current concepts and provides insight into the application of MDCT-derived 3DCM and 3D printing for the planning of transcatheter mitral valve replacement and closure of paravalvular leaks. Additionally, future directions in the development of 3DCM will be discussed.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Estudos Retrospectivos
15.
Eur Heart J Case Rep ; 5(1): ytaa573, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33521516

RESUMO

BACKGROUND: Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) occurs in up to 1.5% of patients within the first year. The development of an aorto-atrial fistula (AAF) is a rare but problematic complication of IE, which can be confirmed with transoesophageal echocardiography (TOE). We present an exceptional case of occluding an aorto-left atrial fistula only diagnosed with intraprocedural TOE during a subsequent procedure of MitraClip implantation. CASE SUMMARY: A 79-year-old symptomatic male patient with multiple comorbidities was referred due to severe mitral regurgitation (MR). He has had prior TAVI which was complicated with streptococcal IE for which he had received prolonged antibacterial therapy. Transthoracic echocardiography (TTE) revealed severe MR. The patient was accepted for a MitraClip procedure by the heart team. Intra-procedural TOE revealed also a significant continuous shunt through an AAF which was likely caused by the endocarditis. The strategy was therefore defined as to occlude the fistula with an Amplatzer Vascular Plug II 12 mm. The plug was released in the fistula leaving an insignificant residual shunt. After the transseptal puncture one MitraClip XTR was implanted, reducing the MR to mild. After the procedure, the patient's general clinical condition improved without signs of haemolysis. The pre-discharge TTE confirmed trace residual shunt, mild residual MR and mild paravalvular leakage. DISCUSSION: Our case illustrates a complex transcatheter structural heart intervention with improvised procedural strategies based on the intra-procedural TOE findings. We conclude that the pre-procedural TOE needs to be comprehensive rather than exclusive, particularly in the context of bioprosthesis-related endocarditis.

16.
Catheter Cardiovasc Interv ; 98(5): E737-E745, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33533544

RESUMO

BACKGROUND: The MANTA vascular closure device (VCD) is dedicated to large bore access closure and associated with favorable results in selected study populations. Anatomical predictors for access site complications are lacking. AIM: To evaluate MANTA in a real-world population and identify predictors for vascular complications. METHODS: All patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) between January 2016 and May 2020 with MANTA closure were included. Baseline characteristics were collected, pre-procedural computed tomography and post-deployment femoral angiograms were analyzed for anatomical differences. The primary endpoint was a composite of access site related major and minor vascular complications at 30 days follow-up according to the VARC-2 definitions. Secondary endpoints included bleeding, time to hemostasis, procedural length and incomplete arteriotomy closure or arterial occlusion by angiography. A Cox proportional hazards model was used to compare all-cause mortality for patients with and without an access site complication. RESULTS: The 512 patients underwent TAVR with MANTA access closure. Median age was 80 (IQR 75-85), 53% was male, median BMI was 26.4 kg/m2 (IQR 23.4-29.7). Access site related major- or minor vascular complication occurred in 20 (4%) and 23 (4%) of patients respectively. Median time to hemostasis was 42 s (IQR 28-98). Post deployment angiogram showed an occlusion in 24 patients (5%), incomplete closure in 60 patients (12%) or both in three patients (1%). Of these 87 patients, 36 (41%) had a vascular complication. Femoral artery diameter (OR 0.70 [0.53-0.93]), low- (OR 3.47 [1.21-10.00]) and high (OR 2.43 [1.16-5.10]) arteriotomies were independent predictors for vascular complications. CONCLUSION: In this contemporary TAVR population, access-site related complications occurred in 8% of patients and were mainly due to percutaneous closure device failure. Small artery diameter and off-target punctures were independent predictors.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Angiology ; 72(5): 465-473, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33464117

RESUMO

Little data are available on access strategy outcomes for cardiac catheterizations in patients with prior coronary artery bypass graft surgery (CABG). We investigated the effect of transradial access (TRA) and transfemoral access (TFA) on short-term major vascular complications (MVC) and long-term major adverse cardiovascular events (MACE). In this single-center, retrospective cohort study, 1084 patients met our inclusion criteria (TRA = 469; TFA = 615). The cumulative incidence for the primary safety endpoint MVC at 30 days (a composite of major bleeding, retroperitoneal hematoma, dissection, pseudoaneurysm, and arteriovenous fistula) was lower with TRA (0.7% vs 3.0%, P < .01) and this difference remained significant after propensity score adjustment (odds ratio: 0.24; 95% CI, 0.07-0.83; P = .024). The cumulative incidence for the primary efficacy endpoint MACE at 36 months (a composite of all-cause mortality, myocardial infarction, stroke, and urgent target vessel revascularization) was 28.6% with TRA and 27.6% with TFA, respectively. Kaplan-Meier curves showed no difference for the primary efficacy endpoint (P = .65). Contrast use (mL) was significantly lower with TRA (130 [100-180] vs 150 [100-213], P < .01). In conclusion, in patients with prior CABG, TRA was associated with significantly fewer short-term MVC and contrast use, but not with a difference in long-term MACE, compared with TFA.


Assuntos
Cateterismo Cardíaco , Cateterismo Periférico , Ponte de Artéria Coronária , Artéria Femoral , Artéria Radial , Idoso , Cateterismo Cardíaco/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Meios de Contraste/administração & dosagem , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Feminino , Humanos , Incidência , Masculino , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/epidemiologia
19.
Acta Cardiol ; 76(2): 185-193, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31920151

RESUMO

BACKGROUND: Elevated pulmonary artery pressure (PAP) in patients with severe aortic stenosis (AS) is a strong predictor of adverse prognosis. This study sought to assess the relation between PAP and clinical and echocardiographic parameters in elderly patients with severe AS, as well as to identify the determinants of the change in PAP after transcatheter aortic valve implantation (TAVI). METHODS: The study included 170 subjects (age 81 ± 7 years, 45% men) with symptomatic severe AS who were treated by TAVI. They underwent a clinical evaluation and a transthoracic echocardiography before the TAVI procedure and 6 months after. RESULTS: In a multivariable analysis, the independent predictors for baseline PAP were the body mass index (BMI) (ß = 0.21, p = .006), COPD GOLD class (ß = 0.20; p = .009), the E/e' ratio (ß = 0.20; p = .02) and the degree of aortic regurgitation (ß = 0.20; p = .01). After TAVI, there was significantly less (51% vs. 29%, p<.0001) pulmonary hypertension, defined as a tricuspid regurgitation velocity ≥2.8 m/s. The baseline variables related to an improvement in PAP were the tricuspid regurgitation velocity (p = .0001) and the E/e' (p = .005). From the parameters potentially modified with TAVI, the only independent predictor of PAP variation was the change in the E/e' ratio (ß = 0.23; p = .01). CONCLUSIONS: Independent predictors for baseline PAP in elderly patients with symptomatic AS were the BMI, GOLD class, the aortic regurgitation and the E/e' ratio. The baseline predictors for a change in PAP 6 months after TAVI were the baseline PAP and E/e', with only the change in the E/e' ratio being correlated to the change in PAP.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Pressão Arterial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem
20.
Catheter Cardiovasc Interv ; 98(4): 671-677, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33022098

RESUMO

OBJECTIVES: To validate novel dedicated 3D-QCA based on the software to calculate post PCI vessel-FFR (vFFR) in a consecutive series of patients, to assess the diagnostic accuracy, and to assess inter-observer variability. BACKGROUND: Low post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) predicts future adverse cardiac events. However, FFR assessment requires the insertion of a pressure wire in combination with the use of a hyperemic agent. METHODS: FAST POST study is an observational, retrospective, single-center cohort study. One hundred patients presenting with stable angina or non ST-elevation myocardial infarction, who underwent post PCI FFR assessment using a dedicated microcatheter were included. Two orthogonal angiographic projections were acquired to create a 3D reconstruction of the coronary artery using the CAAS workstation 8.0. vFFR was subsequently calculated using the aortic root pressure. RESULTS: Mean age was 65±12 years and 70% were male. Mean microcatheter based FFR and vFFR were 0.91±0.07 and 0.91±0.06, respectively. A good linear correlation was found between FFR and vFFR (r = 0.88; p <.001). vFFR had a higher accuracy in the identification of patients with FFR values <0.90, AUC 0.98 (95% CI: 0.96-1.00) as compared with 3D-QCA AUC 0.62 (95% CI: 0.94-0.74). Assessment of vFFR had a low inter-observer variability (r = 0.95; p <.001). CONCLUSION: 3D-QCA derived post PCI vFFR correlates well with invasively measured microcatheter based FFR and has a high diagnostic accuracy to detect FFR <0.90 with low inter-observer variability.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Estudos de Coortes , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Retrospectivos , Software , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...